Understanding the Impact of Coil Thickness & Input Current on DC Linear Actuator Performance

DC Linear Actuator

Coil heat generation critically impacts the lifespan, efficiency, and repeatability of DC linear actuators. This application note details an electrothermal simulation examining the effects of variables like coil thickness and input currents on heat distribution under various design conditions. It utilizes temperature-dependent material properties to predict actuator temperature changes over time, factoring in the electrical resistivity variations of the coil material.

Figures 1 and 2 present the original and simulated 3D CAD models of the actuator, respectively. Non-magnetic components, irrelevant to magnetic outcomes but potentially influencing thermal results, were excluded from this analysis. Additionally, the simulation considers the spring's effect in motion studies when integrated with magnetic analyses.

3D CAD model of the DC actuator, a) original model, b) simulated model
Figure 1 - 3D CAD model of the DC actuator, a) original model, b) simulated model
 

Figure 2 depicts the simulated DC actuator's components, highlighting the moving plunger and actuator core crafted from 12L14 carbon steel. The coil bobbin, designed for insulation, is made from FEP material.

Different components of the simulated DC actuator

Figure 2 - Different components of the simulated DC actuator

Simulation & Results

1- Variable Plunger position

In magnetic static simulations, heat generation results exclusively from the Joule Effect within conductors carrying current, making it the sole source of ohmic losses.

The Ohmic loss or winding loss is expressed by the following relation: P equals 0.5 asterisk times rho asterisk times integral J ² d v Where is the electrical resistivity of the coil material and is the current density of the coil.

Thus, both Ohmic loss and coil temperature directly correlate with the coil material and current density. With the coil material constant, variations in current density are achieved by altering the coil dimensions. In this analysis, while the input current remains fixed, coil dimensions are adjusted to impact current density, primarily influenced by the coil's cross-sectional area. The key variable under investigation is the coil thickness, as demonstrated in Figure 3.

 Parametrized dimension
Figure 3 - Parametrized dimension
 

Figures 4a) and 4b) provide full and cross-section views of the magnetic field distribution for a coil thickness of 2.2mm, the maximum accommodated by the actuator's design. In these configurations, the magnetic field intensity is approximately 0.55T in the actuator core and reaches up to 2T in the moving plunger.

 Magnetic flux density at a coil thickness of 2.2mm, a) full model view, b) cross section view
 
Figure 4 - Magnetic flux density at a coil thickness of 2.2mm, a) full model view, b) cross-section view
 

Figures 5a) and 5b) display full and cross-section views of the magnetic field distribution for a coil thickness of 1.1mm, revealing identical magnetic field results to the previous scenario due to the constant input current. Figure 6 provides a vector plot illustrating the magnetic flux distribution.

Magnetic flux density at a coil thickness of 1.1mm, a) full model view, b) cross section view

Figure 5 - Magnetic flux density at a coil thickness of 1.1mm, a) full model view, b) cross-section view
 
 
Cross section view of the magnetic field vector plot 
Figure 6 - Cross-section view of the magnetic field vector plot
 

Figure 7 illustrates that current density is inversely proportional to coil thickness, peaking at 1.31e+7 Amp/m^2 with a 1.1mm thickness and dropping to 6.59e+6 Amp/m^2 at 2.2mm. Figure 8 plots Ohmic losses against coil thickness, showing a decrease from 2.65W at 1.1mm to 1.34W at 2.2mm, due to the increase in coil volume with thickness. Temperature trends are expected to mirror these variations.

 The coil current density results versus its thickness
Figure 7 - The coil current density results versus its thickness

The coil Ohmic loss versus its thickness

Figure 8 - The coil Ohmic loss versus its thickness
 

The figure below demonstrates that coil resistance varies linearly with thickness, increasing from 0.094 Ohm at a thickness of 1.1mm to 0.106 Ohm at 2.2mm.

DC resistance of the coil versus thickness 
Figure 9 - DC resistance of the coil versus thickness
 

Figures 10a) and 10b) showcase the steady-state temperature distribution within the actuator for coil thicknesses of 1.1mm and 2.2mm, respectively. At a 1.1mm thickness, the temperature reaches 132°C, while at 2.2mm, it reduces to approximately 80°C. The highest temperature is observed at the coil, the primary heat source, with lower temperatures in components in contact with the coil. As the coil thickness increases, heat spreads more extensively throughout the model, as depicted in Figure 10b). Figure 11, displaying temperature variation against coil thickness, mirrors the trend observed in current density variation.

The actuator temperature results, a) with coil thickness of 1.1mm, b) with coil thickness of 2.2mm 
Figure 10 - The actuator temperature results, a) with coil thickness of 1.1mm, b) with coil thickness of 2.2mm
 
 Temperature variation versus the coil thickness
Figure 11 - Temperature variation versus the coil thickness

2- Temperature Variation versus Coil current

In this analysis, the coil thickness is fixed at 2.2mm while the input current is adjusted, ranging from 1A to 5A in increments of 0.35A for the simulation. 


Input current versus simulation scenarios

Figure 12 - Input current versus simulation scenarios
 

The magnetic flux density results at an input current of 1A, depicted in Figures 13a) and 13b), show a maximum magnetic field of approximately 1.29T in the moving plunger. When the input current increases to 5A, the magnetic field peaks at 2.15T, as illustrated in Figures 14a) and 14b).

 Magnetic flux distribution at 1A, a) full model, b) cross section view
Figure 13 - Magnetic flux distribution at 1A, a) full model, b) cross-section view

 
 
 Magnetic flux distribution at 5A, a) full model, b) cross section view
Figure 14 - Magnetic flux distribution at 5A, a) full model, b) cross-section view
 

Figure 15 demonstrates the current density results against varying input current rates, showcasing a linear relationship with the input current. Ohmic losses as a function of coil currents are plotted in Figure 16, further illustrating the impact of input current variations on the actuator's performance.

Current density versus applied current                                                                                 
Figure 15 - Current density versus applied current
 
Ohmic loss versus input current
Figure 16 - Ohmic loss versus input current
 

Figures 17a) and 17b) present cross-section plots of the actuator's steady-state temperature at applied currents of 1A and 5A, respectively. At 1A, the actuator's temperature is predicted to range between 30°C and 32°C, whereas at 5A, it escalates significantly, varying from 110°C to 174°C. In both scenarios, the highest temperature is recorded in the coil, from where it disperses throughout the actuator until thermal equilibrium is reached.

Cross section view of the temperature distribution, a) at 1A, b) at 5A

Figure 17 - Cross-section view of the temperature distribution, a) at 1A, b) at 5A
 

Figure 18 displays the actuator's maximum temperature against various applied current rates, illustrating a temperature increase corresponding to the rise in input current, as previously detailed.

 Temperature evolution versus applied current
Figure 18 - Temperature evolution versus applied current

Thermal Analysis in case of temperature-dependent material property

In the concluding section, the copper coil is characterized by temperature-dependent electrical resistivity, highlighting how copper's electrical conductivity decreases as temperature increases—resulting in higher electrical resistivity with rising temperatures. Consequently, as the temperature deviates from ambient, the copper winding's electrical resistivity grows, leading to an increase in Ohmic losses. Figure 20 depicts the coil's Ohmic losses over time and temperature, supporting the notion that copper loss escalates linearly over time, stabilizing at 2.33W after thirty minutes, indicating the attainment of a steady state.

The copper electrical conductivity versus temperature

Figure 19 - The copper electrical conductivity versus temperature
 
The coil Ohmic losses versus both temperature and time 
Figure 20 - The coil Ohmic losses versus both temperature and time
 

Given the temperature-responsive nature of the coil material, its resistance is similarly impacted. Figure 21 presents a plot of the coil's DC resistance in relation to both time and temperature, demonstrating an increase in resistance with temperature. The resistance starts at 0.1035 Ohm at ambient temperature and reaches a steady state of 0.1295 Ohm after thirty minutes, underscoring the direct relationship between temperature elevation and resistance augmentation in the coil.

RD resistance of the coil actuator versus both temperature and time 
Figure 21 - RD resistance of the coil actuator versus both temperature and time
 

Figure 22 details the temperature variation of the coil, mirroring the progression of Ohmic losses. The temperature escalates from 25°C at the initial moment (t=0) to a steady state temperature of 90.03°C at 1800 seconds (t=1800 s). The steady-state temperature distribution of the actuator, capturing the comprehensive thermal dynamics over time, is plotted in Figure 23.

 Temperature evolution of the coil versus time
Figure 22 - Temperature evolution of the coil versus time
 
 
 Temperature distribution of the actuator after half hour
Figure 23 -Temperature distribution of the actuator after half an hour

Conclusion

The electrothermal simulation presented in this application note offers a comprehensive analysis of the heat generation and temperature distribution in a DC linear actuator, crucial for its efficiency and longevity. By examining the impact of variables like coil thickness and input currents on heat distribution, the study provides valuable insights into optimizing the actuator's design for improved performance. Figures and plots depict magnetic field distribution, current density, Ohmic losses, and temperature variations under different conditions, elucidating the intricate relationship between design parameters and thermal dynamics. Key findings include the direct correlation between coil thickness and temperature, as well as the linear relationship between input current and actuator temperature. Additionally, the consideration of temperature-dependent material properties, such as copper's electrical resistivity, highlights the importance of accounting for thermal effects in actuator design. Overall, this analysis offers valuable guidance for engineers and researchers seeking to enhance the reliability, efficiency, and repeatability of DC linear actuators through optimized design and operation strategies.